APPLICATION METHODS | |||||||||||||||||||||||||||||||
RC-3000 can be applied by either brush, spray, or roller. Best results can be obtained with airless spray equipment.
The following table provides basic airless spray equipment information.
See Inland Application Bulletins for additional information. | |||||||||||||||||||||||||||||||
APPLICATION CONDITIONS | |||||||||||||||||||||||||||||||
The temperature of the ambient air and substrate should be within a range of 50° - 120° F. RC 3000 should not be applied when the relative humidity is above 90% or when rain is expected. | |||||||||||||||||||||||||||||||
SURFACE PREPARATION | |||||||||||||||||||||||||||||||
The surface must be clean, dry and free of dirt, oil or other contaminates. This is normally best achieved by power washing the surface. Spray nozzle should be held an adequate distance from the surface to prevent roof damage. Make sure all drains are free of debris or blockage. Allow roof to dry thoroughly before any product applications. | |||||||||||||||||||||||||||||||
RC-3000 HANDLING & STORAGE | |||||||||||||||||||||||||||||||
Do not allow coating in pail to freeze. Store in a cool, dry, well-ventilated atmosphere. Avoid prolonged breathing of vapors and prevent contact with eyes. Read all label information and precautions before using. | |||||||||||||||||||||||||||||||
RC-3000 TECHNICAL DETAILS | |||||||||||||||||||||||||||||||
|
RC-3000 Overview
Printable RC-3000 Spec Sheet (PDF)
RC-3000 MSDS