DF-1000 Rubber Deck Filler Specifications
[Application Methods]   [Temperatures]   [Surface Prep]   [Handling & Storage]   [Details]

APPLICATION METHODS
  DF-1000 can be applied by brush, roller or airless sprayer. (See Inland Application Bulletins for additional information)
APPLICATION TEMPERATURE
  For best results, the temperature of the ambient air and the substrate should be within a range of 50°-110°F.
SURFACE PREPARATION
  The surface must be free of any moisture, rust scale or soil. Remove any loose material from cracks or seams with a wire brush or scraper. Oil and grease should also be removed. In many cases water blast will be sufficient to prepare the surface.
DF-1000 HANDLING & STORAGE
  DF-1000 contains a blend of solvents which is considered combustible by D.O.T. and O.S.H.A. standards. It should be used and stored away from flames in a well-ventilated area. Avoid prolonged breathing of vapors and prevent contact with eyes. Read all label information and precautions before using.
DF-1000 TECHNICAL DETAILS
 
Product Type:Spray
Flash Point:105° F.
Specific Gravity:1.0
Weight:8.32 lb./gal.
Solids (% by Weight):51.0 ± 1%
Solids (% by Volume):39.0 ± 1%
Elongation (ASTM-D-412):700%
The specifications, properties and performance of materials described herein are based on information believed to be reliable. Product specifications are subject to change without notice.

DF-1000 Overview
Printable DF-1000 Spec Sheet (PDF)
DF-1000 MSDS

P.O. Box 247, Adel, IA 50003   |   515.993.4251   |   800.456.8467   |   Fax: 515.993.4324   |   info@inlandcoatings.com